Critical CareHemodynamic Monitoring

Hemodynamic Monitoring

MAP ≥65, CVP 2–8, CO 4–8 L/min — each shock type has a distinct hemodynamic fingerprint.

  • Lesson 8 of 8
  • 7 min read

Overview

Hemodynamic monitoring measures the pressures and flows of the cardiovascular system to guide resuscitation and vasoactive drug therapy in critically ill patients.

Key Parameters & Normal Ranges

A single number should never be treated in isolation; MAP, CVP, PCWP, CO, CI, SVR, urine output, mentation, lactate, and skin signs must fit together.

Pressures on the filling side (CVP, wedge) show preload; output and resistance show how well the heart pumps against the vessels. Read them together with the patient.
Pressures on the filling side (CVP, wedge) show preload; output and resistance show how well the heart pumps against the vessels. Read them together with the patient.
ParameterNormal RangeSignificance
MAP (Mean Arterial Pressure)70–105 mmHg (target ≥65 in shock)Driving pressure for organ perfusion; goal in sepsis protocol
CVP (Central Venous Pressure)2–8 mmHgEstimates right heart preload; low = hypovolemia; high = overload
PCWP / PAWP8–12 mmHgReflects left heart preload via pulmonary artery catheter
CO (Cardiac Output)4–8 L/minVolume of blood the heart pumps per minute
CI (Cardiac Index)2.5–4 L/min/m²CO corrected for body size; better for individual patients
SVR (Systemic Vascular Resistance)800–1200 dyne·s/cm⁻⁵Afterload; high = vasoconstricted; low = vasodilated

Shock Hemodynamic Profiles

Each shock type has a fingerprint.

An empty heart is hypovolaemic shock. A full heart that cannot pump is cardiogenic shock. Wide, dilated vessels are distributive shock.
An empty heart is hypovolaemic shock. A full heart that cannot pump is cardiogenic shock. Wide, dilated vessels are distributive shock.
Shock TypeCVP/PCWPCOSVRTreatment
Hypovolemic↓ ↓↓↑IV fluids, blood products
Cardiogenic↑ ↑↓↑Inotropes (dobutamine), diuretics, revascularization
Distributive (Septic)↓↑ early → ↓ late↓ ↓Fluids, vasopressors (norepinephrine)
Obstructive (PE/tamponade)↑↓↑Remove obstruction — thrombolytics, pericardiocentesis

Arterial Line (A-Line)

Leveling at the phlebostatic axis after position changes prevents false high or low readings that could drive unsafe vasoactive titration.

  • Provides continuous beat-to-beat blood pressure monitoring and convenient access for blood draws.
  • Transducer must be leveled at the phlebostatic axis (4th intercostal space, mid-axillary line) every time the patient changes position.
  • Never flush forcefully — risk of air embolism or retrograde flow to the brain (radial artery).
  • Assess insertion site, waveform morphology, and distal circulation (Allen's test before radial A-line insertion).
An arterial line gives the blood pressure beat by beat. Level the transducer at the phlebostatic axis after every position change, or the reading will be wrong.
An arterial line gives the blood pressure beat by beat. Level the transducer at the phlebostatic axis after every position change, or the reading will be wrong.

Pulmonary Artery Catheter (Swan-Ganz)

Because insertion and wedging can cause dysrhythmias, pulmonary artery injury, or infection, the readings must answer a clinical question.

  • Balloon-tipped catheter advanced into the pulmonary artery to measure PCWP, CO, and mixed venous oxygen saturation (SvO₂).
  • Complications: pneumothorax, dysrhythmias, pulmonary artery rupture, infection, and catheter knotting.
  • Wedge pressure measured when balloon inflated briefly in a wedged position; deflate immediately after reading.
  • Less common now — replaced by less invasive monitoring in many ICUs.
The balloon-tipped catheter passes through the right heart into the pulmonary artery to measure wedge pressure and output. Watch for dysrhythmias as it goes through.
The balloon-tipped catheter passes through the right heart into the pulmonary artery to measure wedge pressure and output. Watch for dysrhythmias as it goes through.

Vasopressors & Inotropes

Vasopressors primarily raise vascular tone and MAP, while inotropes primarily improve contractility and cardiac output.

  • Norepinephrine (Levophed): first-line vasopressor in septic shock — increases SVR and MAP.
  • Dobutamine: inotrope — increases CO in cardiogenic shock; can cause tachycardia and hypotension.
  • Dopamine: dose-dependent (low = renal; mid = cardiac; high = vasopressor). Less commonly used now.
  • Vasopressin: adjunct vasopressor at fixed dose (0.04 units/min); spares other vasopressor doses.
  • All vasopressors require central line and continuous hemodynamic monitoring.
A vasopressor such as norepinephrine tightens the vessels to raise the MAP. It runs on a pump, through a central line where possible, and is titrated to a target, not a fixed rate.
A vasopressor such as norepinephrine tightens the vessels to raise the MAP. It runs on a pump, through a central line where possible, and is titrated to a target, not a fixed rate.

Key nursing points

  • MAP = (SBP + 2×DBP) ÷ 3. Target ≥65 mmHg for organ perfusion.
  • CVP: 2–8 mmHg. Low = hypovolemia; high = fluid overload or right heart failure.
  • CO = HR × SV (stroke volume). Normal: 4–8 L/min.
  • SVR: elevated = vasoconstriction (cardiogenic, hypovolemic); low = vasodilation (septic/distributive).
  • Arterial line: transducer leveled at phlebostatic axis (4th ICS, mid-axillary line).
EXAM TRAPCommon exam trapMAP ≥65 mmHg is the SEPSIS BUNDLE target — not just 'good blood pressure.' If MAP < 65 despite 30 mL/kg IV fluid bolus, start vasopressors (norepinephrine is first-line). Dobutamine is an INOTROPE — it increases CO but can drop BP; not used to raise BP alone.

Test yourself

Pick your answer first, then open the rationale. Guessing teaches nothing.

In one line

MAP ≥65, CVP 2–8, CO 4–8 L/min — each shock type has a distinct hemodynamic fingerprint.

For exam prep only — not medical advice. Always follow your institution's clinical protocols and consult licensed professionals.

— 8 —

Finish lesson

Save your completion

Sign in to record progress, sync completion, and keep your study streak accurate.

Sign in to mark complete

Tip: use the ← / → arrow keys to flip pages

  • Sepsis: Recognition & Bundles

    Life-threatening organ dysfunction from dysregulated infection response.

  • Burns & Rule of 9s

    Depth, %TBSA, Parkland formula, airway first in inhalation injury.

  • Shock: Types & Management

    Hypovolemic · Cardiogenic · Distributive · Obstructive.

  • Trauma Medications

    Trauma-related medication use depends on the problem: stabilize ABCs first, then treat pain, agitation,…

  • ARDS

    ARDS is acute inflammatory lung injury with noncardiogenic pulmonary edema, severe hypoxemia, and stiff lungs.

  • Mechanical Ventilation

    Mechanical ventilation supports oxygenation and ventilation when the patient cannot maintain a patent airway…

  • Chest Tubes & Pleural Drainage

    3-chamber water-seal system: collection, water seal, suction control. Tidaling = good; continuous water-seal…