MAP ≥65, CVP 2–8, CO 4–8 L/min — each shock type has a distinct hemodynamic fingerprint.
Lesson 8 of 8
7 min read
Overview?
Overview
Hemodynamic monitoring measures the pressures and flows of the cardiovascular system to guide resuscitation and vasoactive drug therapy in critically ill patients.
Key Parameters & Normal Ranges?
1
Key Parameters & Normal Ranges
A single number should never be treated in isolation; MAP, CVP, PCWP, CO, CI, SVR, urine output, mentation, lactate, and skin signs must fit together.
Pressures on the filling side (CVP, wedge) show preload; output and resistance show how well the heart pumps against the vessels. Read them together with the patient.
Parameter
Normal Range
Significance
MAP (Mean Arterial Pressure)
70–105 mmHg (target ≥65 in shock)
Driving pressure for organ perfusion; goal in sepsis protocol
CVP (Central Venous Pressure)
2–8 mmHg
Estimates right heart preload; low = hypovolemia; high = overload
PCWP / PAWP
8–12 mmHg
Reflects left heart preload via pulmonary artery catheter
CO (Cardiac Output)
4–8 L/min
Volume of blood the heart pumps per minute
CI (Cardiac Index)
2.5–4 L/min/m²
CO corrected for body size; better for individual patients
SVR (Systemic Vascular Resistance)
800–1200 dyne·s/cm⁻⁵
Afterload; high = vasoconstricted; low = vasodilated
Shock Hemodynamic Profiles?
2
Shock Hemodynamic Profiles
Each shock type has a fingerprint.
An empty heart is hypovolaemic shock. A full heart that cannot pump is cardiogenic shock. Wide, dilated vessels are distributive shock.
Leveling at the phlebostatic axis after position changes prevents false high or low readings that could drive unsafe vasoactive titration.
Provides continuous beat-to-beat blood pressure monitoring and convenient access for blood draws.
Transducer must be leveled at the phlebostatic axis (4th intercostal space, mid-axillary line) every time the patient changes position.
Never flush forcefully — risk of air embolism or retrograde flow to the brain (radial artery).
Assess insertion site, waveform morphology, and distal circulation (Allen's test before radial A-line insertion).
An arterial line gives the blood pressure beat by beat. Level the transducer at the phlebostatic axis after every position change, or the reading will be wrong.
Pulmonary Artery Catheter (Swan-Ganz)?
4
Pulmonary Artery Catheter (Swan-Ganz)
Because insertion and wedging can cause dysrhythmias, pulmonary artery injury, or infection, the readings must answer a clinical question.
Balloon-tipped catheter advanced into the pulmonary artery to measure PCWP, CO, and mixed venous oxygen saturation (SvO₂).
Complications: pneumothorax, dysrhythmias, pulmonary artery rupture, infection, and catheter knotting.
Wedge pressure measured when balloon inflated briefly in a wedged position; deflate immediately after reading.
Less common now — replaced by less invasive monitoring in many ICUs.
The balloon-tipped catheter passes through the right heart into the pulmonary artery to measure wedge pressure and output. Watch for dysrhythmias as it goes through.
Vasopressors & Inotropes?
5
Vasopressors & Inotropes
Vasopressors primarily raise vascular tone and MAP, while inotropes primarily improve contractility and cardiac output.
Norepinephrine (Levophed): first-line vasopressor in septic shock — increases SVR and MAP.
Dobutamine: inotrope — increases CO in cardiogenic shock; can cause tachycardia and hypotension.
Dopamine: dose-dependent (low = renal; mid = cardiac; high = vasopressor). Less commonly used now.
Vasopressin: adjunct vasopressor at fixed dose (0.04 units/min); spares other vasopressor doses.
All vasopressors require central line and continuous hemodynamic monitoring.
A vasopressor such as norepinephrine tightens the vessels to raise the MAP. It runs on a pump, through a central line where possible, and is titrated to a target, not a fixed rate.
Key nursing points
MAP = (SBP + 2×DBP) ÷ 3. Target ≥65…
CVP
CO = HR × SV (stroke volume). Normal
SVR
Arterial line
Key nursing points
MAP = (SBP + 2×DBP) ÷ 3. Target ≥65 mmHg for organ perfusion.
CVP: 2–8 mmHg. Low = hypovolemia; high = fluid overload or right heart failure.
⚠EXAM TRAPCommon exam trapMAP ≥65 mmHg is the SEPSIS BUNDLE target — not just 'good blood pressure.' If MAP < 65 despite 30 mL/kg IV fluid bolus, start vasopressors (norepinephrine is first-line). Dobutamine is an INOTROPE — it increases CO but can drop BP; not used to raise BP alone.
Test yourself?
Test yourself
Pick your answer first, then open the rationale. Guessing teaches nothing.
Question 1 of 8
A patient's hemodynamic monitoring shows: CO 3.2 L/min, SVR 1,800 dynes, CVP 14 mmHg, PCWP 22 mmHg. Which hemodynamic profile does this represent?
Answer: Cardiogenic shock — high preload/filling pressures, low CO, high SVR Cardiogenic shock profile: low CO/CI (pump failure), elevated filling pressures (CVP >12 and PCWP >18 = backup of fluid behind failing left ventricle), high SVR (compensatory vasoconstriction). Treatment: inotropes (dobutamine), diuretics (reduce preload), vasodilators (reduce afterload). Septic shock: high CO, low SVR, low filling pressures. Hypovolemic: low CO, low CVP/PCWP, high SVR.
Question 2 of 8
A nurse is monitoring a patient's arterial line. The waveform suddenly shows a flat, damped tracing. What is the priority action?
Answer: Obtain a manual blood pressure and troubleshoot the arterial line system A damped arterial line waveform is unreliable for blood pressure measurement. The nurse first obtains a manual cuff pressure to ensure the patient is hemodynamically stable, then troubleshoots: check for air bubbles (flush), kinked tubing, clot at catheter tip (gentle aspiration), or loose connections. Never blindly flush an arterial line — this can cause arterial air embolism. Removing the line is a last resort.
Question 3 of 8
A patient's cardiac output is 4.8 L/min and body surface area is 2.0 m². What is the cardiac index, and is it within normal limits?
Answer: CI = 2.4 L/min/m² — below normal (normal 2.5–4.0) Cardiac Index (CI) = Cardiac Output ÷ Body Surface Area = 4.8 ÷ 2.0 = 2.4 L/min/m². Normal CI = 2.5–4.0 L/min/m², so a CI of 2.4 is below normal and should be reported. CI corrects CO for body size, making it more accurate for assessing cardiac function across different patient sizes. A CI <2.0 is associated with cardiogenic shock.
Question 4 of 8
A critically ill patient has a central venous pressure of 14 mmHg. The nurse assesses the patient's lungs and notes bilateral crackles and 3+ pitting edema. Which interpretation is MOST accurate?
Answer: CVP 14 mmHg is elevated (normal 2–6 mmHg) — indicates fluid overload or right-sided heart failure. Central venous pressure reflects right atrial filling pressure and right ventricular preload; a CVP of 14 mmHg significantly exceeds the normal range of 2–6 mmHg, indicating elevated right-sided pressures consistent with fluid overload, right-sided heart failure, or tricuspid regurgitation. Combined with pulmonary crackles and peripheral edema, this presentation warrants fluid restriction and diuretic therapy.
Question 5 of 8
The nurse is setting up an arterial line for a patient in the ICU. Which step is the MOST critical to ensure accurate blood pressure readings?
Answer: Zero the transducer at the level of the phlebostatic axis (4th intercostal space, mid-axillary line) with the stopcock open to air. Zeroing the transducer eliminates the effect of atmospheric pressure and positions the reference point at the right atrium level (phlebostatic axis — 4th ICS at mid-axillary line); failure to zero correctly or maintaining the transducer at the wrong height introduces systematic errors in all pressure readings. Re-zeroing should be performed with each position change and at least every 8 hours.
Question 6 of 8
A patient with a pulmonary artery catheter has a pulmonary artery wedge pressure (PAWP) of 22 mmHg. The nurse knows the normal is 6–12 mmHg. How should the nurse interpret this finding?
Answer: The elevated PAWP reflects increased left ventricular end-diastolic pressure, indicating left-sided heart failure or fluid overload. Pulmonary artery wedge pressure estimates left atrial pressure and left ventricular end-diastolic pressure (LVEDP); a PAWP above 18 mmHg indicates elevated left-sided filling pressures, consistent with left ventricular failure or volume overload, and is associated with pulmonary edema. This finding in the clinical context guides diuretic therapy and afterload reduction.
Question 7 of 8
A patient in septic shock has a MAP of 58 mmHg after 30 mL/kg of IV fluids. What is the priority intervention?
Answer: Begin norepinephrine Per Surviving Sepsis guidelines, if MAP remains <65 mmHg after adequate fluid resuscitation, vasopressors (norepinephrine first-line) should be initiated.
Question 8 of 8
When leveling the arterial line transducer, where should the nurse position it?
Answer: At the phlebostatic axis (4th ICS, mid-axillary line) The phlebostatic axis approximates the level of the right atrium and is the standard reference point for hemodynamic pressure transducers.
In one line
MAP ≥65, CVP 2–8, CO 4–8 L/min — each shock type has a distinct hemodynamic fingerprint.
— 8 —
Finish lesson
Save your completion
Sign in to record progress, sync completion, and keep your study streak accurate.