Critical CareMechanical Ventilation

Mechanical Ventilation

Mechanical ventilation supports oxygenation and ventilation when the patient cannot maintain a patent airway or adequate gas exchange.

  • Lesson 6 of 8
  • 8 min read

Overview

Nurses monitor the patient, not just the ventilator: airway security, breath sounds, ABGs, SpO2, hemodynamics, comfort, and complications.

trachea larynx bronchi airway anatomy
A tube bypasses the upper airway to deliver positive-pressure breaths directly to the lungs.

Pathophysiology

Positive-pressure ventilation pushes air into the lungs to improve oxygenation and carbon dioxide removal.

The ventilator pushes air in under positive pressure. That improves gas exchange, but it also raises chest pressure, lowers venous return, and can drop the blood pressure.
The ventilator pushes air in under positive pressure. That improves gas exchange, but it also raises chest pressure, lowers venous return, and can drop the blood pressure.

Signs & Symptoms

Agitation, fatigue, altered mental status, rising CO2, falling SpO2, or weak cough can mean the patient is losing the work-of-breathing battle.

  • Need for ventilatory support: hypoxemia, hypercapnia, apnea, severe fatigue, altered mental status, or inability to protect airway.
  • Ventilator distress: agitation, dyssynchrony, high peak pressures, falling SpO2, unequal breath sounds, hypotension, or absent end-tidal CO2.
  • Tube displacement may present with sudden respiratory distress, decreased breath sounds, or low-pressure alarms.
When the alarm sounds, look at the patient before the screen. If the problem is not found fast, disconnect and bag by hand.
When the alarm sounds, look at the patient before the screen. If the problem is not found fast, disconnect and bag by hand.

Diagnosis

ABGs and end-tidal CO2 show ventilation, SpO2 and FiO2 needs show oxygenation, and chest x-ray plus breath sounds confirm tube position and lung expansion.

  • Use ABGs, pulse oximetry, end-tidal CO2, chest x-ray for tube placement, and physical assessment.
  • Confirm endotracheal tube position, cuff pressure, secured depth marking, and bilateral breath sounds.
  • Trend plateau pressure, peak pressure, tidal volumes, minute ventilation, and patient-ventilator synchrony.
The cuff seals the trachea so air goes to the lungs and secretions stay out. Check its pressure and the tube depth at the lip every shift.
The cuff seals the trachea so air goes to the lungs and secretions stay out. Check its pressure and the tube depth at the lip every shift.

Treatment

Ventilator settings are adjusted to solve a specific problem: FiO2 and PEEP primarily improve oxygenation, while respiratory rate and tidal volume primarily affect CO2 removal.

  • Adjust FiO2 and PEEP for oxygenation; adjust respiratory rate or tidal volume for ventilation as ordered.
  • Provide analgesia and sedation using the lowest effective dose with daily awakening/readiness assessments when appropriate.
  • Suction only when indicated and preoxygenate if needed.
  • Begin spontaneous awakening and breathing trials when the patient meets weaning criteria.
FiO2 and PEEP fix oxygenation; rate and tidal volume fix carbon dioxide. Keep the circuit connected and free of pooled water.
FiO2 and PEEP fix oxygenation; rate and tidal volume fix carbon dioxide. Keep the circuit connected and free of pooled water.

Nursing Priorities

Assess chest rise, breath sounds, SpO2, pulse, blood pressure, tube depth, and circuit integrity, and manually ventilate if the patient is unstable or the ventilator problem cannot be fixed immediately.

  • Assess the patient first when alarms sound: airway, chest rise, breath sounds, SpO2, hemodynamics, and LOC.
  • Keep bag-valve-mask and suction available at the bedside.
  • Maintain HOB elevation, oral care, cuff pressure monitoring, DVT prophylaxis, stress-ulcer prophylaxis, and turning schedules.
  • Communicate worsening ABGs, increasing oxygen needs, new hypotension, or suspected pneumothorax immediately.
Head of the bed at 30 to 45 degrees, regular oral care, and a daily sedation break are the bundle that prevents ventilator-associated pneumonia.
Head of the bed at 30 to 45 degrees, regular oral care, and a daily sedation break are the bundle that prevents ventilator-associated pneumonia.

Patient Teaching

Teaching should focus on communication methods, why the tube must stay secure, and what distress signs require staff attention.

  • Explain that the tube prevents speech; provide communication boards or writing tools when appropriate.
  • Teach family not to pull lines or silence alarms and to alert staff for distress.
  • After extubation, report stridor, increasing work of breathing, or inability to clear secretions.

Complications

Excess pressure can cause barotrauma, high FiO2 can contribute to oxygen toxicity, and sedation plus immobility increase delirium, weakness, and infection risk.

  • Ventilator-associated pneumonia, barotrauma, pneumothorax, hypotension, oxygen toxicity, tracheal injury, delirium, and ICU weakness.
  • Unplanned extubation or mainstem intubation can cause rapid hypoxia.
Too much pressure overstretches the lung until it tears. The air escapes into the chest and the lung collapses: that is barotrauma.
Too much pressure overstretches the lung until it tears. The air escapes into the chest and the lung collapses: that is barotrauma.

Key nursing points

  • Indications include GCS 8 or lower, inability to protect airway, severe work of breathing, refractory hypoxemia, and ventilatory failure.
  • Basic settings: FiO2, tidal volume, respiratory rate, PEEP, mode, pressure limits, and alarm limits.
  • High-pressure alarm: kink, coughing, biting tube, secretions, bronchospasm, pneumothorax, or decreased compliance.
  • Low-pressure alarm: disconnection, cuff leak, or tube displacement.
  • VAP prevention: HOB 30-45 degrees, oral care with chlorhexidine per policy, suctioning, sedation breaks, and early mobility.
  • Never silence alarms without assessing the patient and the ventilator circuit.
EXAM TRAPCommon exam trapNever silence ventilator alarms from the doorway. Assess the patient first, then the airway and circuit; disconnect and manually ventilate if the ventilator is failing and the patient is unstable.

Test yourself

Pick your answer first, then open the rationale. Guessing teaches nothing.

In one line

Mechanical ventilation supports oxygenation and ventilation when the patient cannot maintain a patent airway or adequate gas exchange.

For exam prep only — not medical advice. Always follow your institution's clinical protocols and consult licensed professionals.

— 6 —

Finish lesson

Save your completion

Sign in to record progress, sync completion, and keep your study streak accurate.

Sign in to mark complete

Tip: use the ← / → arrow keys to flip pages

  • Sepsis: Recognition & Bundles

    Life-threatening organ dysfunction from dysregulated infection response.

  • Burns & Rule of 9s

    Depth, %TBSA, Parkland formula, airway first in inhalation injury.

  • Shock: Types & Management

    Hypovolemic · Cardiogenic · Distributive · Obstructive.

  • Trauma Medications

    Trauma-related medication use depends on the problem: stabilize ABCs first, then treat pain, agitation,…

  • ARDS

    ARDS is acute inflammatory lung injury with noncardiogenic pulmonary edema, severe hypoxemia, and stiff lungs.

  • Chest Tubes & Pleural Drainage

    3-chamber water-seal system: collection, water seal, suction control. Tidaling = good; continuous water-seal…

  • Hemodynamic Monitoring

    MAP ≥65, CVP 2–8, CO 4–8 L/min — each shock type has a distinct hemodynamic fingerprint.